Nexcem ICF Thermal Performance
Our Insulated concrete forms in R-value, between R-8 and R-36. The Nexcem material has an R-value of 2.00 per inch. This means that all Wall Forms regardless of thickness have a basic R-value of R-8 to R-12. We increase the R-value by incorporating additional insulation inserts into the Wall Form at the time of manufacture. The inserts are made from mineral fiber insulation (Rockwool) and are also completely fire-resistant and made from recycled content. The inserts are placed inside the Wall Form cavity but positioned towards the exterior to maximize the Thermal Mass effects of the wall system.
Description | Thickness | Height | Length | Concrete Core | Insulation Insert | R-Value |
6″ WF R-8 | 6″ | 12″ | 24″ | 3.2″ | none | R-8 |
8″ WF R-8 | 8″ | 12″ | 36″ | 5″ | none | R-8 |
10″ WF R-8 | 10″ | 12″ | 36″ | 7″ | none | R-8 |
10″ WF R-14 | 10″ | 12″ | 36″ | 5.5″ | 1.5″ | R-14 |
12″ WF R-8 | 12″ | 12″ | 24″ | 8.5″ | none | R-8 |
12″ WF R-14 | 12″ | 12″ | 24″ | 7″ | 1.5″ | R-14 |
12″ WF R-22 | 12″ | 12″ | 24″ | 5.5″ | 3″ | R-22 |
14″ WF R-8 | 14″ | 12″ | 24″ | 10.5″ | none | R-8 |
14″ WF R-14 | 14″ | 12″ | 24″ | 9″ | 1.5″ | R-14 |
14″ WF R-22 | 14″ | 12″ | 24″ | 7.5″ | 3″ | R-22 |
14″ WF R-28 | 14″ | 12″ | 24″ | 5.5″ | 5″ | R-28 |
16″ WF R-8 | 16″ | 12″ | 24″ | 12.5″ | none | R-8 |
16″ WF R-14 | 16″ | 12″ | 24″ | 11″ | 1.5″ | R-14 |
16″ WF R-22 | 16″ | 12″ | 24″ | 9″ | 3″ | R-22 |
16″ WF R-28 | 16″ | 12″ | 24″ | 7.5″ | 5″ | R-28 |
16″ WF R-36 | 16″ | 12″ | 24″ | 5.5″ | 7″ | R-36 |
The Wall System Summary and the Technical Guide provide the steady-state two dimensional R-values for our wall systems.